NEMA NEMA Wiring Device Section WD6 Wiring Devices- Dimensional Specifications UL 498

 
2008 NECŪ Article 406.11 requires tamper-resistant receptacles in Dwelling Units.* In all areas specified in 210.52 all 125-volt, 15- and 20-ampere receptacles shall be listed tamper-resistant receptacles.

2008 NECŪ effective January 1, 2008.

*A Dwelling Unit is a single unit, providing complete and independent living facilities for one or more persons, including permanent provisions for living, sleeping, cooking, and sanitation.

States Adopting NEC Code
Implementation will be state-by-state. View anticipated state adoption map now




Other Applicable Codes and Standards
  • 2008 NEC (registered mark) section 517.18(C) Pediatric Locations. Receptacles located within the rooms, bathrooms, playrooms, activity rooms, and patient care areas of pediatric wards shall be listed under tamper resistant or employ a listed tamper resistant cover.

  • 2008 NEC Section 406.8 outdoor receptacles. All 15- and 20-ampere, 125- and 250-volt receptacles in damp or wet locations must be Weather-Resistant.



How Can You Help?
  • Support adoption of tamper-resistant receptacles for the 2008 NEC.
  • Refute misinformation with the facts.



NEMA is the leading trade association in the U.S. representing the interests of electroindustry manufacturers of products used in the generation , transmission and distribution , control, and end-use of electricity.